PSAM Myers Pump: What It Is and Why It Matters

The shower went cold, the pressure sagged to a dribble, then nothing. A dead-quiet pressure gauge at 0 PSI. When a well pump quits, your home stops—no cooking, bathing, laundry, livestock watering, or answers for a worried family. In my years sizing and troubleshooting systems, the pattern is consistent: the “savings” from a bargain pump vanish the first time you’re hauling five-gallon buckets across the yard.

Meet the Eltori family. Omar Eltori (41), a high school math teacher, and his spouse, Priya (39), a remote software analyst, live on 6 acres outside Scio, Oregon with their kids Mira (10) and Kian (7). Their 240-foot private well had been limping along on a 3/4 HP budget submersible rated for 10 GPM—undersized for the 55 PSI Priya likes for showers and the garden irrigation Omar runs weekends. Sand fines in the water column and a summer thunderstorm finished the job: a burnt motor and cracked staging on their old Red Lion unit after 3.5 years. One frantic Saturday call later, we spec’d a Myers Predator Plus with a Pentek XE motor, and the difference was immediate—steady pressure, silent operation, long-view reliability.

This list is the blueprint I gave the Eltoris: materials matter, motors matter, and proper sizing matters. We’ll cover stainless construction, Teflon-impregnated impellers, Pentek XE high-thrust efficiency, 2-wire vs 3-wire decisions, warranty power, field-serviceable design, pump curve sizing, installation best practices, must-have accessories, and emergency-readiness. If you rely on a private well—rural homeowner, licensed contractor, or emergency buyer—these ten points are the fastest path to dependable water with a PSAM-supplied Myers Pump.

—Rick Callahan, Technical Advisor at Plumbing Supply And More (PSAM)

#1. Predator Plus Build Quality – 300 Series Stainless Steel, Threaded Assembly, and UL/CSA Confidence

A well pump lives submerged in an unforgiving environment; corrosion, sand, and pressure cycling punish weak materials. That’s why a 300 series stainless steel build is non-negotiable for long, quiet service.

Myers Predator Plus submersibles use 300 series stainless on the shell, discharge bowl, shaft, coupling, wear ring, and suction screen. This lead-free, corrosion resistant architecture resists acidic pH, high mineral content, and stray current effects that destroy cast iron. The threaded assembly design means serviceable staging without junking the entire pump—a practical advantage in the field. PSAM myers pump Every unit is UL listed, CSA certified, and factory tested before it leaves the plant. Pair those fundamentals with an internal check valve and sturdy intake screen, and you’ve got a submersible built to run under real-world abuse.

The Eltoris’ retired Red Lion had thermoplastic components that cracked under pressure cycling and grit impact. Their new Myers submersible well pump—Predator Plus 1 HP—arrived from PSAM ready for duty: stainless throughout, tight tolerances, and a clean discharge thread that mated perfectly to 1-1/4" NPT drop pipe.

Material Science That Pays Off

Stainless resists pitting and crevice corrosion that quickly compromise cast iron or thermoplastic housings. In variable chemistry wells, 300 series simply lasts, especially at shafts and couplings where micro-movement can abrade softer alloys. Result: fewer lock-ups, smoother operation, less shaft runout over time.

Serviceability in the Field

The threaded assembly lets a qualified tech disassemble stages, inspect wear rings, and replace parts without tossing the entire pump. In remote areas—think rural Oregon foothills—that’s a game-changer for cost and downtime.

Certifications and Confidence

Being UL listed and CSA certified is more than a stamp. It signals insulation integrity, thermal protection performance, and assembly consistency. When the pump sits 200+ feet down, those details matter more than packaging claims.

Key takeaway: Stainless, certified, and serviceable—Predator Plus is a structural investment that keeps water flowing.

myers grinder pump

#2. Pentek XE High-Thrust Motor – 80%+ Efficiency Near BEP, Thermal and Lightning Protection Built In

Your pump only performs as well as its motor. The Pentek XE motor backing Myers Predator Plus units delivers high-thrust torque, thermal overload protection, integrated lightning protection, and low amperage draw for long-term efficiency.

With an 80%+ hydraulic efficiency when operated near the best efficiency point (BEP), these motors convert electricity into useful work cleanly. The result is up to 20% annual energy savings versus generic motors, plus cooler winding temperatures that extend lifespan. Designed for continuous duty in 230V single-phase systems, Pentek XE motors keep service factors high enough to handle back-to-back demands—washer, irrigation, shower—without thermal trips.

When Omar and Priya upgraded to a 1 HP Predator Plus matched to their TDH and flow needs, the new motor stopped the hot/bothered cycling that had plagued their weekends. Pressure recovered faster. Lights didn’t flicker on starts. And the bill? Down a measurable 11% month over month compared to the old draw.

Why Thrust Matters

Deep wells load motors axially. High-thrust designs support impeller stacks under static head and start-up torque. Without that margin, bearings fail. With Pentek XE, axial loads are a solved problem.

Protection That Saves Pumps

Voltage spikes and heat are pump killers. Thermal overload protection stops windings from cooking. Integrated lightning protection buffers transients—a meaningful layer in storm-prone regions.

Right-Sized Amperage

Lower amperage draw translates to reduced heat and breaker nuisance trips. It also allows practical wire gauge usage over long drops, protecting your budget and your voltage at depth.

Bottom line: efficient thrust and real protections give you reliable water and lower lifetime costs.

#3. Teflon-Impregnated Staging – Self-Lubricating Impellers That Stand Up to Sand and Grit

Grit eats pumps. If your aquifer carries fines, your impeller material determines how often you replace a submersible. Myers uses Teflon-impregnated staging with self-lubricating impellers—an engineered composite that rides out abrasion better than plain plastic or metal vanes.

As water with fines passes through the multi-stage pump, each stage shares the work, adding pressure efficiently while minimizing localized erosion. Myers’ engineered composite maintains geometry longer, so the pump stays on its pump curve deeper into life. You’ll see this as stable pressure at your faucets and fewer unexplained short-cycling events.

The Eltori well tests showed fines presence, especially after summer drawdowns. The new Predator Plus shrugged it off where the old staging cracked and lost vane edge. After installation, Mira’s evening showers and Omar’s drip zones ran simultaneously without the weak pulse they’d learned to tolerate.

Composite vs. Metal Reality

Metal impellers sound tough but lose leading edge sharpness in gritty water, eroding the efficiency window. Myers’ composite holds profile and lubricates itself under boundary-layer flow—less wear, quieter operation.

Stage-by-Stage Discipline

Even pressure increase per stage reduces turbulence. Combined with a wear ring designed for tight clearances, you keep leak-back minimal and output predictable—vital for pressure switch stability.

Maintenance Made Minimal

With composite staging, you’re not greasing bearings monthly or chasing mystery pressure drops. This is set-and-forget durability that homeowners notice on day 400 as much as day 4.

Result: fewer parts failures, fewer callbacks, and water that behaves like it should.

#4. Real-World Efficiency vs Competitors – Stainless, Motor Tech, and Warranty That Outlasts Goulds and Red Lion

When choosing between mid-range and premium pumps, materials and motor design are the whole story. Myers Predator Plus uses 300 series stainless steel and a Pentek XE motor tuned for 80%+ efficiency near BEP. Goulds submersibles often integrate cast iron components that corrode in acidic or mineral-rich wells; Red Lion leans on thermoplastic housings susceptible to cracking from heat and pressure cycling. Over five years, corrosion and plastic fatigue show up as pressure instability, rising amperage draw, and bearing noise.

Installation and maintenance diverge, too. Myers’ field serviceable threaded assembly allows on-site stage inspections and part swaps. Goulds and Red Lion paths more often mean complete unit replacement when staging or housings fail. Then consider service life: homeowners routinely see 8–15 years from Myers, with 20+ possible under ideal water and maintenance. Red Lion customers frequently report 3–5 years; Goulds can do better, but acidic water attacks their mixed-metal construction. Stack energy bills, replacement frequency, and downtime, and the math is clear.

If your property depends daily on a private well, Myers’ stainless, efficient motor, and PSAM support network are worth every single penny.

#5. Sizing That Stops Short-Cycling – 1/2 HP Through 2 HP, GPM Curves, and Total Dynamic Head Accuracy

Wrong size equals short life. Correctly pairing horsepower and GPM rating to TDH (total dynamic head) is the difference between a happy pressure tank and nightly breaker resets.

For most homes:

    1/2 HP or 3/4 HP covers 60–150 ft wells at 8–12 GPM. 1 HP hits 150–300 ft at 10–15 GPM. 1.5 HP–2 HP reach 300–490 ft or serve higher-flow needs, like irrigation.

We calculated the Eltori system at ~260 feet TDH: 240-foot static depth, 15 feet of elevation to the tank, and friction losses equal to ~5 psi. Their 1 HP Myers Predator Plus in a 12–15 GPM configuration planted them at BEP for smooth pressure and low amperage.

Calculating TDH the Right Way

Start with static water level, add pumping lift to the highest fixture, include friction loss for your drop pipe and lateral piping, and translate desired pressure (e.g., 50 psi) into feet (psi x 2.31). That’s your TDH.

Reading the Pump Curve

A pump curve tells you the flow you’ll get at a given head. Aim your operating point in the upper-middle of the curve—your BEP—for 80%+ efficiency and cool motor temps.

When to Up-Stage

If you’re near the curve’s edge, add stages or step up to the next HP. Running a motor hot and off-curve is how windings, thrust bearings, and impellers die early.

Rick’s recommendation: call PSAM with depth, static level, pressure target, and pipe runs—we’ll land you on the right curve the first time.

#6. 2-Wire vs 3-Wire Decisions – Simplicity, Control Boxes, and Long-Term Serviceability

Both 2-wire well pump and 3-wire well pump systems have their place. Myers offers both, and the choice is about simplicity vs. control preferences.

A 2-wire configuration packs the start components in the motor—no external control box—which simplifies installation and can shave $200–$400 in upfront costs. Fewer connections mean fewer failure points. A 3-wire setup uses an external control box where capacitors and relays live above-ground, which some contractors prefer for quick diagnostics and component swaps.

For the Eltoris, a 2-wire Predator Plus made sense: straight swap, minimized connections, and no box to mount in their tight utility corner.

When 2-Wire Wins

Shorter install time, fewer parts, and clean wiring runs. Beneficial for emergency replacements and DIY-friendly projects with PSAM phone support.

When 3-Wire Shines

Service-centric contractors like above-ground access to start components. In long-term service markets, a control box swap at year 10 can be cheaper than a pull.

Voltage and Amperage Notes

Most residential installs run 230V single-phase. Verify breaker sizing and wire gauge for your motor’s amperage draw and run length to avoid voltage drop.

Choose the route that fits your service philosophy; either way, Myers motors give you the reliability you’re after.

#7. Warranty and Proven Lifespan – 3-Year Coverage, 8–15 Years Typical, 20–30 Years With Care

Coverage is confidence. Myers backs Predator Plus with an industry-leading 3-year warranty—a full 36 months that outpaces the 12–18 month windows common in the market. In my files, well-maintained Myers units run 8–15 years consistently, with clean-water, well-sized installs stretching beyond 20.

After swapping the Eltoris’ failed pump, we documented the system: pressure switch cut-in/out at 40/60 PSI, tank precharge at 38 PSI, good check valve function, and balanced flow demand. That baseline—plus annual tank checks—sets their Predator Plus up for the long haul.

What the Warranty Signals

A manufacturer only stretches coverage when failure rates are low. The 3-year blanket is a bet on material integrity, Pentek XE motor reliability, and real-world abuse testing.

How to Reach 20 Years

Hit your BEP, keep fittings tight, protect against dry-run, service your pressure tank annually, and lightning-protect the panel. Pumps die from heat, mis-sizing, and neglect.

What to Document

Store your well depth, static level, installed HP, GPM model, install date, and PSAM invoice. In a rare event you need support, everything moves faster.

image

Reliability is planned, not luck. Myers and PSAM stack the deck in your favor.

#8. Field Serviceability vs Franklin – Threaded Access, Non-Proprietary Maintenance, and Contractor-Friendly Repairs

A deep well shouldn’t lock you into proprietary service. Myers’ field serviceable design uses a threaded assembly that any qualified contractor can open, inspect, and repair. Contrast that with some Franklin Electric submersible configurations that pair motors with proprietary control ecosystems and channel service through specialized dealer networks.

Performance-wise, Predator Plus delivers stainless construction, Teflon-impregnated staging, and Pentek XE motor efficiency. In the field, those advantages turn into fewer full-pull replacements and more economical part-level fixes. Franklin makes fine motors, but tying homeowners to dealer-only diagnostics elongates downtime and can inflate maintenance costs over the life of the well. With Myers, if a stage needs attention or a wear ring shows unusual clearance, your contractor has a straightforward path to remedy without replacing the entire unit.

For rural families like the Eltoris, access is everything. In a 4-hour window between school pickups and work calls, their installer pulled the drop, verified staging, set a new safety rope and torque arrestor, and had them back with pressure before dinner. In my book, serviceability that keeps families in water is worth every single penny.

#9. Installation Best Practices – From Pitless Adapter to Pressure Switch, Do It Right Once

Even the best pump suffers if installed poorly. Follow a proven checklist and your system will reward you with quiet, consistent pressure.

The Eltoris upgrade included a new pitless adapter seal, torque arrestor, safety rope, and fresh wire splice kit with heat-shrink connectors. We verified the pressure switch at 40/60, set the tank precharge to 38 PSI with water drained, and checked the check valve for tight shut.

Drop Pipe and Discharge Size

Use 1-1/4" rated drop pipe to the pump’s discharge size. Undersized pipe elevates friction loss and amps. On long runs, schedule 80 PVC or stainless drop pipe holds alignment and resists bowing.

Electrical and Controls

Run correct gauge for amperage draw and depth; confirm clean splices with dual-wall heat shrink. Keep controls accessible and dry. If you choose 3-wire, mount the control box on vibration-free backing.

Start-Up and Purge

Prime lines slowly, purge air through hose bibs, then check for sand. If fines appear, flush until clear and document. New installations can release construction fines for an hour or two.

Do it right and don’t touch it again for years—that’s the whole point.

#10. Application Range That Grows With You – From Shallow Jet to Deep Submersible and Backup Pressure

A “Myers Pump” isn’t just one model. It’s a portfolio that lets you match application and budget with confidence.

    For deep wells: Predator Plus Series submersible well pump models span 1/2 HP to 2 HP, 7–20+ GPM rating, and up to ~490 ft shut-off head. For shallow systems: Myers jet pump options shine up to ~50 feet and make quick work of cistern or rainwater transfer. For drainage or basements: a Myers sump pump is a quiet insurance policy. For tough wastewater: a Myers grinder pump or sewage pump is built for the job.

Omar’s forward plan includes a small orchard and a future greenhouse tap. Building on a 1 HP Predator Plus at 12–15 GPM keeps that door open without re-pulling the well.

Residential, Irrigation, and Livestock

Whether a residential well water system or a small pasture line, sizing from the same brand family keeps service uniform and Myers pump parts easy to source.

Pressure Boosters and Add-Ons

If the home sits on a hill or long lateral runs sap pressure, consider a booster pump staged after storage or treatment. Myers options integrate nicely with standard tank tee packages.

Future-Proofing

Choose a curve that leaves 10–20% capacity headroom. It’s cheap insurance against tomorrow’s projects.

When you can scale without swapping brands, ownership gets simpler and cheaper.

Detailed Comparison: Myers vs Goulds and Grundfos – Materials, Configs, and Real Cost Over 10 Years

On paper, premium brands often look similar. In practice, construction and configuration flexibility separate winners from near-misses. Myers Predator Plus leans into full 300 series stainless steel wetted components and Teflon-impregnated staging for long wear in mineral-charged or mildly acidic water. Goulds has strong engineering but still deploys cast iron elements in several lines; that invites corrosion in challenging chemistries. Grundfos builds efficient pumps with smart controls but often nudges buyers toward 3-wire or integrated control ecosystems that increase upfront costs and complicate simple replacements. Myers gives you both 2-wire simplicity and 3-wire serviceability options with proven Pentek XE motor efficiency.

In the ground, these differences dictate installation time and long-term service. Myers’ field serviceable threaded design means stage inspections without a full replacement. Goulds’ mixed-metal assemblies and Grundfos’ control-centric approaches often push owners into higher-cost solutions or dealer-only servicing. Over 10 years, stack Myers’ 3-year warranty, energy savings near BEP, and fewer replacements due to stainless construction, and the total cost of ownership advantage compounds.

For rural homes where uptime is non-negotiable, the balanced equation of materials, motor tech, and serviceability makes Myers, through PSAM, worth every single penny.

FAQ: Your Most Pressing Myers Pump Questions, Answered

1) How do I determine the correct horsepower for my well depth and household water demand?

Start with your total dynamic head (TDH): add static water level to lift to the highest fixture, convert desired pressure to feet (PSI x 2.31), and include friction loss in your piping. Then match that TDH to a pump curve for your target flow. Typical homes need 8–12 GPM; larger homes or irrigation can push 12–20 GPM. As a rule: 1/2–3/4 HP fits 60–150 ft wells; 1 HP fits 150–300 ft; 1.5–2 HP reaches 300–490 ft or supports higher flows. Example: At 260 ft TDH with a 12 GPM target, a Myers Predator Plus 1 HP at the correct staging will sit near its BEP, keeping motor temperature low and efficiency high. My recommendation: call PSAM with your depth, static level, and pipe runs—we’ll place your operating point on the correct Myers curve and select 2-wire or 3-wire based on your service preference.

2) What GPM flow rate does a typical household need and how do multi-stage impellers affect pressure?

Most households run smoothly on 8–12 GPM at 40/60 PSI. A family with irrigation, livestock waterers, or multiple simultaneous showers benefits from 12–20 GPM capacity. Multi-stage impeller stacks increase pressure incrementally per stage, creating higher head at modest motor loads. This is why a 1 HP Myers Predator Plus can deliver 12–15 GPM at 200–300 feet TDH without overheating. The more stages, the more head you build at a given flow, which stabilizes pressure switch operation and reduces short-cycling. In effect, multi-stage designs let you tune the pump to your well depth and pressure goals while keeping efficiency above 80% near BEP—a quieter, longer-lived system.

image

3) How does the Myers Predator Plus Series achieve 80% hydraulic efficiency compared to competitors?

Efficiency lives at the intersection of hydraulic design, materials, and motor performance. Myers uses engineered Teflon-impregnated staging that maintains impeller geometry longer, reducing internal recirculation losses. Tight wear ring tolerances keep leak-back minimal. Pair that with a Pentek XE high-thrust motor whose torque curve aligns with the impeller load line, and you convert more electrical energy into water movement—often 80%+ near the BEP. Many budget pumps lose efficiency early as plastic vanes erode; mixed-metal designs can corrode and open clearances. Practical upshot: the Myers curve you buy is the curve you keep for years, which lowers amperage draw and utility bills.

4) Why is 300 series stainless steel superior to cast iron for submersible well pumps?

Submerged cast iron invites corrosion, especially with acidic pH or high chlorides. Rust creates scale that abrades bearings and impellers, increases friction, and destabilizes pressure. 300 series stainless steel resists pitting and crevice corrosion, preserving dimensional integrity at the shaft, coupling, wear ring, and suction screen. That stability keeps your pump on-curve longer and protects the motor from axial misalignment. It also tolerates temperature swings and pressure cycles without cracking—a common thermoplastic failure mode. For rural wells where chemistry varies season to season, stainless is the only material that truly “disappears” into the background and just works.

5) How do Teflon-impregnated self-lubricating impellers resist sand and grit damage?

Grit attacks the leading edges of impellers and the clearance between the impeller and diffuser. Myers’ self-lubricating impellers—an engineered composite with Teflon-impregnated surfaces—create a low-friction boundary layer, reducing abrasive contact. The material also maintains its edge profile better than plain plastics or soft metals, so efficiency doesn’t nosedive after a few sandy months. Combined with a sturdy intake screen and proper set depth (avoiding the very bottom of the well), these impellers shrug off fines that would chew up budget staging. In practice, that means steady pressure, lower amperage, and fewer rebuilds in wells with seasonal sediment.

image

6) What makes the Pentek XE high-thrust motor more efficient than standard well pump motors?

The Pentek XE is designed around axial load tolerance and efficiency under continuous duty. High-thrust bearings handle the stacked impeller loads typical in deep wells. Windings are optimized to reduce I²R losses, translating to lower amperage draw for a given head/flow point. Integrated thermal overload protection prevents overheats, while built-in lightning protection guards against voltage transients. That combination keeps winding temperatures down and extends insulation life. In real-world terms: fewer nuisance trips, smoother starts, and energy bills trimmed by up to 20% annually versus generic motors misaligned with the pump’s hydraulic profile.

7) Can I install a Myers submersible pump myself or do I need a licensed contractor?

Many capable homeowners complete installs successfully with PSAM guidance, especially on straight 2-wire configuration swaps of the same HP and GPM. That said, I recommend a licensed installer when changing horsepower, revising head/flow targets, or when your well is over 200 feet—drops get heavier, and mistakes cost more. Critical steps include correct wire gauge selection, watertight wire splice kit use (dual-wall heat-shrink), secure pitless adapter connections, proper torque arrestor placement, safety rope attachment, and pressure tank precharge setting. If you DIY, we’ll help you assemble a complete kit—pump, drop pipe, fittings, tape, rope, splice kit—so you can get water back on quickly and safely.

8) What’s the difference between 2-wire and 3-wire well pump configurations?

In a 2-wire well pump, start components live inside the motor—no external control box—streamlining installation and typically reducing upfront cost by $200–$400. Fewer connections mean fewer points of failure. In a 3-wire well pump, the start capacitor and relay are in an above-ground control box. Contractors like the easy access for diagnostics and inexpensive start component replacement down the road. Performance can be similar if sizing is correct; the choice is about service philosophy. Myers offers both, powered by the same Pentek XE motor technology, so you can pick simplicity (2-wire) or maintenance access (3-wire) without sacrificing reliability.

9) How long should I expect a Myers Predator Plus pump to last with proper maintenance?

In my field experience, 8–15 years is a realistic expectation, with many installs crossing 20 years in clean-water, well-sized systems. Key factors: operate near the BEP on the pump curve, keep your pressure tank charged correctly (2 PSI below cut-in), ensure your check valve seats tightly, and protect against dry-run and lightning. Document install data (depth, static level, HP, GPM, date) and do a quick annual review—pressure switch contacts, tank precharge, and a listen for chatter. The 3-year warranty reflects Myers’ low defect curve; your maintenance keeps the curve flat.

10) What maintenance tasks extend well pump lifespan and how often should they be performed?

Annually: verify tank precharge (air at 2 PSI under cut-in), inspect pressure switch contacts, listen for rapid cycling, and scan for leaks at the tank tee and pitless. After major storms: check breaker status, feel for warmth at the control box (3-wire), and note any unusual short-cycling. Every 3–5 years: recheck static water level if possible, confirm amperage draw under load (a rising amp trend can flag impeller wear or bearing drag). Always repair small leaks fast; aerated water hammers pumps. Good operation near BEP and clean electrical connections add years to any submersible—especially a stainless Myers.

11) How does Myers’ 3-year warranty compare to competitors and what does it cover?

Myers’ 3-year warranty outpaces many competitors’ 12–18 month coverage. It addresses manufacturing defects and performance issues under normal residential use. Practically, the extended window covers early-life anomalies that cheaper pumps often fail under—bearing issues, staging defects, or winding problems. With PSAM as your partner, we streamline claims with your documented install details. When stacked against budget brands with 1-year terms, the extended Myers coverage reduces your 10-year ownership cost by mitigating premature replacements and giving you real leverage if a component anomaly appears.

12) What’s the total cost of ownership over 10 years: Myers vs budget pump brands?

A $300–$500 cheaper pump that lasts 3–5 years will be swapped 2–3 times in a decade. Factor in labor (often $600–$1,200 per pull), water downtime, rising electrical inefficiency as staging wears, and the numbers get ugly. A Myers Predator Plus, sized to your curve and installed correctly, spreads its cost across 8–15+ years, uses less power (80%+ efficiency near BEP), and carries a 3-year warranty that catches early-life issues. In my ledger, most homeowners save $1,200–$2,500 over 10 years with Myers compared to budget units, not counting avoided emergencies. Reliability plus efficiency is the real bargain.

Conclusion: PSAM + Myers = Reliable Water, Lower Bills, Fewer Headaches

From the Eltoris’ dead Saturday to a steady 60 PSI Monday, the solution wasn’t luck—it was engineering. 300 series stainless steel to beat corrosion. Teflon-impregnated staging to tame grit. A Pentek XE high-thrust motor to deliver 80%+ efficiency near BEP. 2-wire or 3-wire flexibility to fit your install philosophy. A genuine 3-year warranty to back the promise. And PSAM’s same-day shipping on in-stock units when the house goes dry.

If you want a pump that shows up every day—showers hot, irrigation on time, power bills trim—choose a Myers Predator Plus from PSAM. Call, tell us your depth, static level, pressure goal, and pipe runs. I’ll put you on the right pump curve, kit you with the correct pitless adapter, torque arrestor, check valve, and wire splice kit, and get your water back on fast. For rural families, licensed contractors, and emergency buyers: this is the water solution that’s worth every single penny.